EasyManua.ls Logo

Lenze i550 Series - 1-Phase Mains Connection 230;240 V; Rated Data

Lenze i550 Series
112 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-phase mains connecon 230/240 V
Rated data
Inverter I55AP137B..7 I55AP137D..7 I55AP155B..7 I55AP155D..7 I55AP175B..7 I55AP175D..7
Rated power kW 0.37 0.37 0.55 0.55 0.75 0.75
Rated power hp 0.5 0.5 0.75 0.75 1 1
Mains voltage range 1/PE AC 170 V...264 V, 45 Hz...65 Hz
Output voltage 3 AC 0-230/240 V
Rated mains current
without mains choke A 5.7 5.7 7.6 7.6 10 10
Apparent output power kVA 0.9 0.9 1.2 1.2 1.6 1.6
Rated output current
2 kHz A 2.4 2.4 3.2 3.2 4.2 4.2
4 kHz A 2.4 2.4 3.2 3.2 4.2 4.2
8 kHz A 2.4 2.4 3.2 3.2 4.2 4.2
12 kHz A 2.2 2.2 2.9 2.9 3.8 3.8
16 kHz A 1.6 1.6 2.1 2.1 2.8 2.8
Power loss
2 kHz W 19 19 24 24 30 30
4 kHz W 20 20 25 25 32 32
8 kHz W 24 24 31 31 40 40
12 kHz W 23 23 30 30 38 38
16 kHz W 22 22 28 28 35 35
when the controller is
inhibited
W 6 6 6 6 6 6
Cyclic mains switching 3 mes per minute
Max. shielded motor cable
length
without EMC category m 50 50 50 50 50 50
Category C2 (2 kHz, 4 kHz, 8
kHz)
m 10 - 10 - 10 -
Category C3 (2 kHz, 4 kHz, 8
kHz)
m 35 - 35 - 35 -
Weight kg 1.8 1.7 1.8 1.7 1.8 1.7
Weight lb 4 3.7 4 3.7 4 3.7
Technical data
1-phase mains connecon 230/240 V
Rated data
105