Long connecng cables up to max. 5 m
The brake resistor cable must be shielded. The maximum length is 5 m.
For the temperature monitoring cable, twisng is sucient.
R
B
RB1 RB2
< 5 m
T1 T2
+
"
"
Fig. 17: Connecon plan - br
ake resistor with a cable length of up to 5 m
Wiring to the "brake resistor" connecon on the inverter or another component with brake chopper.
Oponal: Wiring to a control contact, e. g. a digital input that is set to monitor the thermal contact. If the thermal
contact responds, the voltage supply of the inverter must be disconnected (e. g. switch o the control of the mains
contactor).
Electrical ins
tallaon
Brake resistor connecon