Technical data
Standards and operang condions
Conformies and approvals
Conformity
 
CE
2006/42/EC
Machinery Direcve, only relevant for (permissible)
safety components, such as encoder or brake
2014/30/EU EMC Direcve (reference: CE-typical drive system)
EAC
TP TC 020/2011
Eurasian conformity: Electromagnec compability of
technical means
TP TR 004/2011 Eurasian conformity: Safety of low voltage equipment
 
RoHS 2011/65/EU
Restricons on the use of certain hazardous substances
in electrical and electronic devices
Approvals
 
UL UL 61800-5-1
File No. E132659
 
For USA and Canada (requirements of CSA 22.2 No.
274)
Protecon of persons and device protecon
Degree of protecon Data applies for operaonally ready mounted state and
not in wire range of terminals
 
EN EN 60529 IP20
UL
UL 50 Type 1 Only protecon against accidental contact
 
UL 61800-5-1 Open type Only in UL-approved systems
Insulaon resistance
 
Overvoltage category EN 61800-5-1
II > 2000 m amsl
 
III 0 … 2000 m amsl
Isolaon of control circuits
  EN 61800-5-1 Safe line voltage isolaon double/reinforced insulaon
Leakage current
 
AC
EN 61800-5-1
> 3.5 mA
Please observe regulaons and safety instrucons!
 
DC > 10 mA
Starng current
  ≤ 3 x rated mains current
Protecve measures
 
Earth fault resistance
Stalling protecon,
motor
Short-circuit-proof
Overvoltage protecon
 
Overtemperature of
motor
PTC or thermal contact, I²xt monitoring
EMC data
Operaon on public supply systems Compliance with requirements for the machine/system
is the responsibility of the machine/system
manufacturer!
 
> 1 kW, line current ≤ 16
A
EN 61000-3-2
Without addional measures
< 1 kW With mains choke
 
Line current > 16 A EN 61000-3-12
With mains choke or mains
lter
When sizing for rated power.
Noise emission
 
Category C1
EN 61800-3 See rated dataCategory C2
 
Category C3
Noise immunity
  EN 61800-3 Requirements met
Technical data
EMC da
ta
179