Technical data
Standards and operang condions
Conformies and approvals
Conformity
CE
2006/42/EC
Machinery Direcve, only relevant for (permissible)
safety components, such as encoder or brake
2014/30/EU EMC Direcve (reference: CE-typical drive system)
EAC
TP TC 020/2011
Eurasian conformity: Electromagnec compability of
technical means
TP TR 004/2011 Eurasian conformity: Safety of low voltage equipment
RoHS 2011/65/EU
Restricons on the use of certain hazardous substances
in electrical and electronic devices
Approvals
UL UL 61800-5-1
File No. E132659
For USA and Canada (requirements of CSA 22.2 No.
274)
Protecon of persons and device protecon
Degree of protecon Data applies for operaonally ready mounted state and
not in wire range of terminals
EN EN 60529 IP20
UL
UL 50 Type 1 Only protecon against accidental contact
UL 61800-5-1 Open type Only in UL-approved systems
Insulaon resistance
Overvoltage category EN 61800-5-1
II > 2000 m amsl
III 0 … 2000 m amsl
Isolaon of control circuits
EN 61800-5-1 Safe line voltage isolaon double/reinforced insulaon
Leakage current
AC
EN 61800-5-1
> 3.5 mA
Please observe regulaons and safety instrucons!
DC > 10 mA
Starng current
≤ 3 x rated mains current
Protecve measures
Earth fault resistance
Stalling protecon,
motor
Short-circuit-proof
Overvoltage protecon
Overtemperature of
motor
PTC or thermal contact, I²xt monitoring
EMC data
Operaon on public supply systems Compliance with requirements for the machine/system
is the responsibility of the machine/system
manufacturer!
> 1 kW, line current ≤ 16
A
EN 61000-3-2
Without addional measures
< 1 kW With mains choke
Line current > 16 A EN 61000-3-12
With mains choke or mains
lter
When sizing for rated power.
Noise emission
Category C1
EN 61800-3 See rated dataCategory C2
Category C3
Noise immunity
EN 61800-3 Requirements met
Technical data
EMC da
ta
179

Table of Contents

Related product manuals