EasyManua.ls Logo

Lenze i950 Series - Control Connections

Lenze i950 Series
188 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Control connecons
Digital inputs
X3: DI1, DI2, DI3, DI4 / GI
Switching type PNP Parameterizable
Use case 1
Standard digital input
Use case 2
Touch probe input Maximum of 8 markers per ms detectable
with a temporal resoluon of 10 ns.
Switching level PNP
LOW V < + 5 IEC 61131−2, type 1
HIGH V > + 15
Input resistance kΩ 4.6
Sampling frequency of digital
inputs
kHz 4 When used as standard digital input.
MHz 100 When used as touch probe.
Electric strength of external
voltage
V ± 30
Digital outputs
X3: DO1 / 24O / GO
Switching level
LOW V < +  5 IEC 61131-2, type 1
HIGH V > + 15
Max. output current, DO1 mA 50
Cycle me ms 0.25
Short-circuit strength Unlimited period
Electric strength of external
voltage
V ± 30
Suppressor circuit Integrated varistor
Overload behavior Reduced voltage or periodic switch-o/on
Time response µs 250 LOW - HIGH / HIGH - LOW
Reset or switch-on behavior Output is switched o LOW
Connecon descripon Control terminals 24 V supply of control
electronics
PTC input
Connecon X3 X5 X109
Connecon type Pluggable Pluggable Pluggable
Max. cable cr
oss-secon mm² 1.5 2.5 1.5
Max. cable cr
oss-secon AWG 16 12 14
Stripping length mm 9 10 6
Stripping length in 0.35 0.39 0.2
Required tool 0.4 x 2.5
Electrical ins
tallaon
Control connecons
157