Loading...
Saving the parameter sengs
During operaon with the CiA 402 device prole (Parameter 0x4000 = CiA [0]), no sengs are saved. The
sengs are transmied when the master control is started. If applicaons are used, the SD card with the
license data also serves as storage medium.
The acve applicaon is displayed in the parameter. C2013:001
The applicaon can be modied via the parameter. 0x4000
Save parameter sengs with »EASY Starter«
If a parameter seng has been changed with the »EASY Starter« but not yet saved in the memory medium
with mains failure protecon, the status line of the »EASY Starter« displays the note "The parameter set was
changed".
There are 3 opons to save the parameter sengs in the user memory of the storage medium:
Click the buon in the toolbar of the »EASY Starter« .
Press the funcon key F6.
Execute the device command "Save user data": = "On / start [1]".