1-phase mains connecon 230/240 V
Rated data
These inverters do not have an integrated RFI lt
er in the AC mains supply.
In order to meet the EMC requirements according to EN 61800−3, an external EMC lter according
to IEC EN 60939 must be used.
The user must verify that the conformity with EN 61800−3 is fullled.
Inverter I95AE
137D 155D 175D 215D
Rated power P
r
ated
kW 0.37 0.55 0.75 1.5
Rated power P
r
ated
HP 0.5 0.75 1 2
Mains voltage range 1/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0 - 230/240 V
Rated mains current
without mains choke A 5.7 7.6 10 -
with mains choke A 4.8 7.1 8.8 13.9
Apparent output power kVA 0.9 1.2 1.6 2.6
Rated output current
2 kHz A 2.4 3.2 4.2 7
4 kHz A 2.4 3.2 4.2 7
8 kHz A 2.4 3.2 4.2 7
16 kHz A 1.6 2.1 2.8 4.7
Power loss
2 kHz W 34 39 48 73
4 kHz W 35 42 53 81
8 kHz W 40 47 61 98
16 kHz W 40 47 61 98
Cyclic mains switching 3-mal pro Minute
Max. shielded motor cable
leng
th
without EMC category m 50
Category C1 (2 kHz, 4 kHz, 8
kHz)
m -
Category C2 (2 kHz, 4 kHz, 8
kHz)
m -
Category C3 (2 kHz, 4 kHz, 8
kHz)
m -
Weight m kg 1.6
Weight m lb 3.5