Bus-related informaon
Name PROFINET RT
Communicaon medium Ethernet 100 Mbps, full duplex
Use Connecon as PROFINET IO Device
Connecon system RJ45
Status display 2 LEDs
Connecon designaon X256
X257
On-board-EtherCAT
LED "RUN” (green)
Blinking paern State Meaning
o
OFF No supply voltage.
Inialisaon (Init) Network not acve
No data transfer
Blinking 1:1
Pre-Operaonal (Pre-Op) Access possible
No process data transfer
Blinking slowly 3:1
Safe-Operaonal (Sa
fe-Op) States of the safe inputs are readable.
on
Operaonal (Op) Data transfer in acon
LED "L/A" (green)
Blinking paern State Meaning
o Not connected Network not available
on
Connected Network available
No da
ta transfer
blinking
Trac Data transfer
Typical topologies
Line
IN OUT
MD
R
SD15
SD2
SD1
IN OUT INOUT
MD Master
SD Slave Device
Bus-related in
formaon
Designaon On-board EtherCAT
Communicaon medium Ethernet 100 Mbps, full duplex
Use Connecon of the inverter to the
system bus cross communicaon or
as standard EtherCAT slave
Status display 1 LED (RUN)
Connecon designaon IN: X236
OUT: X237
Electrical ins
tallaon
Networks
On-board-EtherCAT