14 Parameter reference
14.3 Parameters of the communication module for slot MXI2
110
Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 11.0 EN · 04/2016 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14902
C14910
C14911
C14912
C14913
C14914
Parameter | Name:
C14902 | Firmware version
Data type: VISIBLE_STRING
Index: 9673 = 0x25C9
The code contains a string with a length of 8 characters. The identification code is displayed (e.g. "01.10.09").
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14910 | I&M1 system designation
Data type: VISIBLE_STRING
Index: 9665 = 0x25C1
Input/output of the I&M1 plant identification code
The Lenze setting shows an empty string.
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14911 | I&M1 installation site
Data type: VISIBLE_STRING
Index: 9664 = 0x25C0
Input/output of the I&M1 location identification code
The Lenze setting shows an empty string.
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14912 | I&M2 installation date
Data type: VISIBLE_STRING
Index: 9663 = 0x25BF
Input/output of the I&M2 date of installation
The Lenze setting shows an empty string.
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14913 | I&M3 additional information
Data type: VISIBLE_STRING
Index: 9662 = 0x25BE
Input/output if the I&M3 additional information
The Lenze setting shows an empty string.
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14914 | I&M4 signature code
Data type: OCTET_STRING
Index: 9661 = 0x25BD
Input/output of the I&M4 signature
The Lenze setting shows an empty string.
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT