EasyManua.ls Logo

Lenze PROFINET 9400 - Diagnostic Data

Lenze PROFINET 9400
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 Diagnostics
12.3 Diagnostic data
84
Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 11.0 EN · 04/2016 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.3 Diagnostic data
The I/O device sends an alarm message to the I/O controller to signalise the diagnostic data
below.
The precondition for transmitting alarm messages is the configuration of process data words in
slot 1 of the PROFINET frame (see Configuring the PROFINET IO controller
( 33)).
Errors and warnings in the Servo Drive 9400 and the plugged-in modules are sent to the I/O
controller as extended diagnostic messages.
With code C13887
/ C14887 the transmission of an alarm message can be suppressed for
specific error messages.
The diagnostic data are shown in code C13867
/ C14867:
Bytes Information
0Slot
1
2Subslot
3
4 Error code
...
7
8Slot
9
10 Subslot
11
12 Error code
...
15
Reference manual/»Engineer« online help for the Servo Drive 9400
Detailed information on the error codes is provided here.

Table of Contents