14 Parameter reference
14.2 Parameters of the communication module for slot MXI1
98
Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 11.0 EN · 04/2016 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13865
C13867
Parameter | Name:
C13865 | Display: Last safety PRM data
Data type: OCTET_STRING
Index: 10710 = 0x29D6
Display of the F_parameters sent last.
• These data are only valid if PROFIsafe is activated.
• The coding of the F_parameters is described in the PROFIsafe profile V2.0.
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Bytes Information
0Slot
1
2Subslot
3
4Recldx
5
6 Accepted length
...
9
10 F_parameter
...
24
Parameter | Name:
C13867 | Display: Most recent diagnostic data
Data type: OCTET_STRING
Index: 10708 = 0x29D4
Display of the diagnostic data sent by the inverter most recently.
Diagnostic data
( 84)
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Bytes Information
0Slot
1
2Subslot
3
4 Error code
...
7
8Slot
9
10 Subslot
11
12 Error code
...
15