6 Commissioning
6.2 Configuring the PROFINET IO controller
34
Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 11.0 EN · 04/2016 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Examples of selecting the device data base file
• "PCD (8W) AR cons." = 8 process data words (only in slot 1 of the PROFINET frame)
• "Safety (4W) AR" = 4 safety data words (only in slot 2 of the PROFINET frame if the SM301 safety
module is used simultaneously)
• "Safety (8W) AR" = 8 safety data words (only in slot 2 of the PROFINET frame if the SM302 safety
module is used at the same time, from SW version 3.00 onwards)
Tip!
A detailed description of consistency is given in the chapter "Consistent parameter data
"
( 75).
Note!
A safety bus system (PROFIsafe) can only be operated via the upper module slot (MXI1)
of the Servo Drive 9400.