6 Commissioning
6.3 Setting the station name
36
Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 11.0 EN · 04/2016 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
In the »Engineer« the station name is set under the Settings tab.
The station name is written to code C13899
/ C14899.
In the Lenze setting a deleted name is displayed. The name is also deleted if the "Reset to factory
defaults" command is executed by an IO supervisor or an I/O controller.
How to activate changed settings in the »Engineer«:
1. Execute the device command C00002 = "11: Save start parameters".
2. Carry out a "Reset node" of the node, or
switch the voltage supply of the communication
module off and then on again