Commissioning
Code table
7
EDK71MMXXX-020 DE/EN/FR 1.0
47
L
Code IMPORTANTPossible settings
No.
IMPORTANT
SelectionLenzeName
C0410
v
(cont.)
Free
configuration of
digital input
signals
13 ... 16 Reserved -255- -90 ... -105- CAN-IN2.W2
Bit 0 (90) ... bit 15 (105)
17 DCTRL1-H/Re -255-
-200- Bit-by-bit assignment of the FIF
control words (FIF-CTRL1,
18 ... 24 Reserved -255-
FIF-CTRL2) f
om the function
module INTERBUS or
PROFIBUS-DP (see C0005)
C0411
Level inversion of
-0-
E5 E4 E3 E2 E1
The binary value of
v
digital inputs E1
2
4
2
3
2
2
2
1
2
0
the selected
...
-0- 00000
num
e
e
e
m
nes
the input levels:
-1- 00001
0: Ex is not inverted
-2- 00010
(HIGH active)
-3- 00011
:
x
s
nve
e
(LOW active)
... ... ... ... ... ...
-31- 11111
C0415
Free
-0-; -255- Not assigned (FIXED-FREE)
Output of digital
v
configuration of
-1-; -2- Reserved
signals to terminals
g
a
ou
pu
s
-3- Motor 1 active
-4- Motor 2 active
-5- Brake active
-6-; -7- Reserved
1 Output A1 -3- -8- starttec inhibit active
(DCTRL1-CINH)
2 Output A2 -4- -9- ... -12- Reserved
3 Output A3 -5- -13- Overtemperature ( ϑ
max
–5 °C)
(DCTRL1-OH-WARN)
4 Output A4 -25- -14-; -15- Reserved
5 Output ASI A1 -255- -16- Ready for operation
(DCTRL1-RDY)
6 Output ASI A2 -255- -17-; -18- Reserved
-19- PTC w arning
(DCTRL1-PTC-WARN)