2
Technical data
Rated data
EDK71MMXXX-020 DE/EN/FR 1.0
L
12
Rated data - motor switch/brake switch
Mains voltage V
r
100 V 0 % Vr 550 V +0 %; 45 Hz ... 65 Hz ±0 %
Max. output current I
r
9.5 A
Motor power
mains voltage 3 230 V P
r
0.25 ... 2.2 kW
mains voltage 3 400 V P
r
0.25 ... 4.0 kW
max. 9.5 A
mains voltage 3 500 V P
r
0.37 ... 5.5 kW
m
a
x
.
9
.
5
A
Brake switch output voltage
mains voltage 3 230 V V
B
205 VDC
mains voltage 3 400 V V
B
180 VDC, 205 VDC
Max. output current of brake switch I
B
0.4 A
Cyclic switching
Motor switch max. 1 / s
Brake control max. 3 / s
Motor temperature monitoring PTC thermistor or thermostat (NC contact)
Phase failure detection yes
Mains failure detection yes
Load failure detection yes, switch off limit programmable