Commissioning
Code table
7
EDK71MMXXX-020 DE/EN/FR 1.0
39
L
Code IMPORTANTPossible settings
No.
IMPORTANT
SelectionLenzeName
C0002
s
U
UU
US
SS
SE
EE
Er
rr
r
(cont.)
Store your own
basic settings
-9- PAR1 ð Own settings You can save your
own basic settings
for starttec
parameters (e. g.
delivery status of
your machine):
1. Ensure that
parameter set 1
is active
2. starttec inhibit
3. Set C0003 = 3,
acknowledge
with
v
4. Set C0002 = 9,
acknowledge
with
v,to
save your own
basic settings
5. Set C0003 = 1,
acknowledge
with
v
6. starttec enable
Loading/copying
of your own ba-
sic settings
-5- Own settings ð PAR1 Restorage of your
own basic settings
C0003
v
U
UU
US
SS
SE
EE
Er
rr
r
Non-volatile
parameter saving
-1-
-0- Do not save parameter in EEPROM Da ta loss after
mains
disconnection
-1- Always sa ve parameter in EEPROM l Ac tive after
every main
connection
l Cyclic
parameter
changes via bus
module are not
allowed.
C0005 Function module
configuration
-0-
-0- All digital input signals are sent via the
internal control terminal strip
-200- All digital input signals are sent via the
fieldfunctionmodule