Commissioning
Code table
7
EDK71MMXXX-020 DE/EN/FR 1.0
45
L
Code IMPORTANTPossible settings
No.
IMPORTANT
SelectionLenzeName
C0356 System bus time
settings
0 {1 ms} 65000
1 Boot up 3000 Required for CAN
network without
master
2 Cycle time
CAN-OUT2
0 0 and C0360 = 0:
event-controlled
process data
transfer
> 0 and C0360 =
1: cyclic process
data transfer
3 Cycle time
CAN-OUT1
0 0=
event-controlled
process data
transfer
>0=cyclic
process data
transfer
4 CAN delay 20 Waiting time until
cyclic sending after
boot up
C0357 System bus
monitoring times
0 {1 ms} 65000
1 CAN-IN1 (sync) 0 Valid if C0360 = 1
2 CAN-IN2 0
3 CAN-IN1 (time) 0 Valid if C0360 = 0
C0358 Reset node -0-
-0- No function
System bus reset
-1- System bus reset
node set-up
C0359 System bus
-0- Operational
Only display
status
-1- Pre-operational
-2- Warning
-3- Bus off
C0360 Control of
-1-
-0- Event or time control
p
ocess
a
a
channel CAN1
-1- Sync c ontrol
C0370 Activation of
-0- Deactivated
Only display
remote
parameter setting
-1- ...
-63-
Aktivates corresponding CAN address
-1- = CAN address
1
-
-=
-255- No system bus (CAN)
-
-=
address 63