7.1.2
P30:
Limit
Switch
Mode
Limit
Switch
contact
mode
can
be
selected:
0
=
Inverse
1
=
Normal
P31:
Variable
Transmission
Mode
Unit:
Quantity
of
SX-1
with
PT-1.
Range:
0
...
64
With
the
Variable
Data
menu,
variable
values
may
be
changed,
and when
correct,
sentto
the
SX-1
by
pressing
the
ENTER
key.
lt
several
axes
are
connected
to
the
PT-1,
then
normally
only
the
selected
axis
is
supplied
with
data.
lt
you
wish
to
supply data
in
parallel
to
several
SX-1
controls,
then
use
Parameter
P31.
For
example:
P31
=
1
P31
=
2
Variable
sent
only
to
selected
Axis.
Variable
sent
to
Axis
No.
0
and
No.
1
P32:
Units
per
Revolution
(U/rev)
Units
(tor
P32):
Units
per
Revolution
Range:
0.000
...
99999.999
The
number
of
„Units
per
Revolution“
is
used,
together
with
the instruction
„Position
Absolute/Direct
Positioning“
(see
Chapter
8)
to
reach
required
position
by
the
shortest
route.
For
a
given
final
position,
the
shortest
distance (clockwise
or
anti-clockwise)
will
depend
on
the
number
of
units
per
revolution.
7/24
Lanze