Device parameters and interfaces
54 BPS 34 Leuze electronic
8.1.7.3 Module 3: Static preset
Note!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
With this module, a preset value can be defined which the BPS 34 outputs following a teach
event. Defined as a teach event is either bit 0.0 in the output data of this module or a
switching input function. After reading in the teach event, the current position value is
replaced by the preset value and the position value is now calculated and output on the basis
of the preset value. The preset remains stored in the BPS 34 and remains active even
following a new start. In order for the BPS 34 to again output the position value without the
preset, bit 0.1 in the output data must be set.
Note!
In the event of a device change, the preset value is retained in the MS 34 10x. The activation
of the preset value (preset teach) at the intended position is not necessary.
Parameters
Note!
The preset value is always entered in units of mm, independent of the resolution setting
(module 2). The scaling factor (module 6) has no effect on the static preset value.
Hex coding of module 3 "Static preset"
The value listed in the table shows the hex coding of the default settings.
Parameter Description Rel.
addr.
Data
type
Value range Default Unit CR to
module
Static pre-
set value in
[mm]
New position value after teach
event
0
unsign
32
0 10,000,000 0 mm
12c
7g
or
3b
Parameter length: 4 byte
a
Internal
address of
module 3
Static preset
06 00 00 00 00