Device parameters and interfaces
60 BPS 34 Leuze electronic
8.1.7.7 Module 7: Switching input
Note!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
The module defines the mode of operation of the digital switching input.
Parameters
Parameter Description Rel.
addr.
Data
type
Value range Default Unit CR to
module
Inversion
The parameter defines the logic
of the applied signal. In case of
an inversion, an external HIGH
level is interpreted as an internal
LOW level.
0
unsign
8
0: No (active high)
1: Yes (active low)
0 ––
Mode
This parameter controls the
release of the switching input.
1
unsign
8
0: Off
1: On
1 ––
Debounce
time in
[ms]
This parameter defines a
debounce time which is imple-
mented via software.
2
unsign
8
0 255 5 ms
Start-up
delay in
[ms]
The parameter influences the
timing during switch-on.
3
unsign
16
0 65,535 0 ms
Pulse dura-
tion in [ms]
The parameter defines the mini-
mum pulse duration of the input
signal.
5
unsign
16
0 65,535 0 ms
a
b
c
d
e