Device parameters and interfaces
Leuze electronic BPS 34 61
TNT 35/7-24V
Hex coding of module 7 "Switching input"
The value listed in the table shows the hex coding of the default settings.
Input data
Switch-off
delay in
[ms]
The parameter defines a time
delay for the signal during switch-
off.
7
unsign
16
0 … 65,535 0 ms –
Function
The parameter specifies the
function which is to be activated
or deactivated by a status
change at the switching input.
9
unsign
8
0: No function
7 –
–
4: Teach preset
3a
or
4c
5: Reset min./max. position 13e
7: Start position mea-
surement
9a
9: Stop position measure-
ment
9b
10: Teach limit value 1
14a
16a
11: Teach limit value 2
15a
17a
12: Reset min./max. speed
22b
24
13: Start speed measure-
ment
22a
14: Stop speed measure-
ment
22b
Parameter length: 10 byte
Internal address
of module 7
Inversion
address 0
Mode
address 1
Debounce time
address 2
Start-up delay
address 3
Pulse duration
address 5
Switch-off delay
address 7
Function
address 9
01 00 01 05 00 00 00 00 00 00 04
Input data Description Rel.
addr.
Data
type
Value range Default Unit CR to
module
State
Signal state of the switching input 0.0 Bit
0: Input is not active
1: Input is active
0 ––
Input data length: 1 byte