6-4
Troubleshooting
Lexicon
The table at the right shows the parameters which comprise a
setup, along with the factory default setting of each parameter.
REINITIALIZATION
Note:
Reinitializing will erase all registers and setups.
The following procedure will return the PCM 81 to the state it was
in when shipped from the factory. This includes erasing all registers
and setups, as well as restoring all of the default settings:
1. Press Control.
2. Use the Up and Down buttons to locate Row 1 System.
3. Turn SELECT to 1.8 Initialize.
4. Press Store. The PCM 81 will display the message "Are you
sure? (Press STORE)".
If you don't want to reinitialize your unit, press any button
except Store to return to matrix position 1.8.
If you press Store in response to this message, the display will
flash "Restoring original factory settings" and your unit will be
reinitialized.
Control Mode
Matrix Location System Parameter Default Setting
Audio 0.0 Word Clock Internal 48kHz
0.1 Analog Lvl 100%
0.2 Digital Lvl 0%
0.3 Word Size 20 bits
0.4 SCMS Multi Copy
0.5 Emphasis Bit Pass Thru
0.6 Output Level +4dBu
System 1.0 Edit Mode Go
1.1 Mix Mode Pgm
Global Mix Value 100% Wet
1.2 Tempo Mode Pgm
Global Tempo Value 120 BPM
1.3 Bypass Mode InputMute
Bypass Src Off
1.4 Pgm Bypass AllMute
1.5 Mem Protect On
1.6 Auto Lock Off
1.7 Patch Update Delayed
MIDI 3.1 Receive OMNI
3.2 Transmit 1
3.3 Pgm Change On
Pgm+ Off
Pgm– Off
Map select 0
Chain MIDI
3.4 Automation Off
3.5 Footpedal None
Sw 1 None
Sw 2 None
ADJUST None
3.6 Int Clock Off
3.7 SysEx On
Device ID 0
3.9 Dump Speed Slow
Tempo Mode
Matrix Location System Parameter Default Setting
Tempo 0.2 Source Internal
Tap 1.3 Display On

Table of Contents