anticlockwise to secure. Make sure fastening is complete by looking at the
bayonet tting and checking it is home.
8.1.5Mountable vibration isolators
The mountable vibration isolators can be used to reduce the transmitted
vibration from the pump to a mounting surface such as a system frame.
The mountable vibration isolators have xing holes to allow the pump to be
bolted to the oor or system frame.
Supplied equipment:
1. 4‑vibration isolators1.
2. 4‑pump xing screws2.
3. 4‑plain washers3.
4. 4‑shake proof washers.4.
Maximum load per isolator 18 kg
Nominal deection 4 mm
Installation
Make sur
e the pump is switched off before tting.
1. Unscrew and remove the standard rubber feet if tted.1.
2. Fit the vibration isolators to the pump using the screws and washers2.
provided.
3. Using 5 mm bolts (not supplied), x the vibration isolators bolted to the3.
xing surface or system frame.
W
e recommend the tting of exible tubing or bellows connections between
the pump-inlet and the pump- outlet and the rest of the system, to prevent
the transmission of stress to the vacuum pipelines and/or equipment.
52 300668736_002_C7 - © Leybold
Accessories