anticlockwise to secure. Make sure fastening is complete by looking at the
bayonet tting and checking it is home.
8.1.5Mountable vibration isolators
The mountable vibration isolators can be used to reduce the transmitted
vibration from the pump to a mounting surface such as a system frame.
The mountable vibration isolators have xing holes to allow the pump to be
bolted to the oor or system frame.
Supplied equipment:
1. 4vibration isolators1.
2. 4pump xing screws2.
3. 4plain washers3.
4. 4shake proof washers.4.
Maximum load per isolator 18 kg
Nominal deection 4 mm
Installation
Make sur
e the pump is switched off before tting.
1. Unscrew and remove the standard rubber feet if tted.1.
2. Fit the vibration isolators to the pump using the screws and washers2.
provided.
3. Using 5 mm bolts (not supplied), x the vibration isolators bolted to the3.
xing surface or system frame.
W
e recommend the tting of exible tubing or bellows connections between
the pump-inlet and the pump- outlet and the rest of the system, to prevent
the transmission of stress to the vacuum pipelines and/or equipment.