42PW350 Power Error History (IN START) Screen
28
June 2011 42PW350 Plasma
IN START
1. Adjust Check
2. ADC Data
3. Power Off Status
4. System 1
5. System 2
6. Model Number D/L
7. Test Option
8. External ADC
9. Pattern Selection
10. Panel Control
11. Spread Spectrum
12. Sync Level
13. Stable Count
14. ODC Test
15. Power Error History
Model Name: 42PW350-UA
Serial Number: 010PTZK1F285
S/W Version:
MICOM Version
SPI Boot Version
BOOT Version
Touch Version
EDID Version (RGB)
EDID Version (HDMI)
Chip Type
3D ASIC Version
Debug Status
Module Rom Ver:
RF Emitter Versioni
UTT : 12
APP History Ver.:53810
PQL DB:LGE_PG_LGT10_xxN42
: 03.26.02.11
: 3.24.0
: 4.24.00
: 0.01.17
: 0.05 (0x00)
: 0.01
: 0.01
: SATURN 7
: 0.77
: RELEASE
: 42T3_4PV3A0
: VB091
1. Last History:
2. Last History:
3. Last History:
4. Error Count
POWER ERROR HISTORY
VA UVP
VS OCP
NONE
1) PFC_DET Error
2) 5V OVP
3) 5V UVP
4) 17V OVP
5) 17V UVP
6) M5V OVP
7) M5V UVP
8) Vs OCP
9) Vs OVP
10) Vs UVP
11) Va OVP
12) Va UVP
5. Reset All
ff
ff
ff
ff
ff
ff
ff
1
ff
ff
ff
1
PFC_DET: Power Factor Control Detect
OVP: Over Voltage Protect
OCP: Over Current Protect
UVP: Under Voltage Protect
Bring up the Service Menu using the Service Remote
by pressing “In-Start” enter password 0413 or 0000.
Select
Item 15