Observe the Picture while making these adjustments Normally they do not have to be done
Set Up and Set Down Adjustments
Set must be in “WHITE WASH”
All other DC Voltage adjustments should have already been made.
.
,
.
ADJUSTMENT LOCATION:
Center Right of the board.
Waveform TP on the Y-Drive Board
Y-Drive Test Point
A
VR601
n
er
u
er
rom
op
SET-UP ADJUST:
1) Adjust VR601 and set the (A) portion of the signal to
match the waveform above. (155V p/p ± 5V)
ADJUSTMENT LOCATION:
SET-DN ADJUST:
2) Adjust VR401 and set the (B) time of the signal to match
the waveform above. (195uSec ± 5uSec)
VR401
TIP: To help lock the scope when capturing the
June 2011 42PW350 Plasma
89
Bottom Right
Just above P101
-
ave
orm, us
e
_
on
e
on
ro
Board for an External Clock.