P101 Y-SUS to Control P101 Plug Voltage Checks
There are No Stand By
Voltages on this Connector
TIP: Use the Control Board (P101) side of this connector to make voltage readings
TIP: The ribbon does not come with a new Y-SUS or Control board.
TIP:
Use
the
Control
Board
(P101)
side
of
this
connector
to
make
voltage
readings
.
P101 "Y-SUS" to P105 "Control"
Pin Label Run Diode Check Pin Label Run Diode Check
28 30
15V
18 2V
1 13V
11
STB
15V
OL
28
~
30
+
15V
18
.
2V
1
.
13V
11
STB
1
.
5V
OL
24~27 +5V 4.94V 1.15V 10 RAMP_BLK 1.07V OL
20~23 Gnd Gnd Gnd 9CLK0.6V OL
19 Dumy2 2.14V OL 8SUS_DN2.71V OL
18
Y
-OE 0.03V 2.02V 7 DUMMY_3 2.14V OL
17 PC 1.84V OL 6 DUMMY_1 1.07V OL
16 ER_DN 0.5V OL 5 DUMMY_4 1.35V OL
15 DATA_PRE 0.01V OL 4SUS_UP_00.75V OL
14
ER UP
03V
OL
3
CTRL OE
0 11V
OL
c
14
ER
_
UP
0
.
3V
OL
3
CTRL
_
OE
0
.
11V
OL
13 SC_A 1.45V OL 2 RAMP_DN 2.17V OL
12 RAMP_UP 0.22V OL 1Gnd Gnd Gnd
Diode Mode Readings
taken with all connectors
Disconnected.
DVM in Diode Mode.
June 2011 42PW350 Plasma
99

Table of Contents