The Z-SUS (in combination with the Y-SUS) generates a SUSTAIN Signal and an ERASE PULSE
for
eneratin
SUSTAIN and DISCHARGE in the Panel.
Z-SUS Waveform
This waveform is supplied to the Z-SUB through P3 and P4 and then to the panel through two
FPC (Flexible Printed Circuit) connections P201 and P202.
Reset
Y Drive
577V p/p
Oscilloscope Connection Point.
J17 to check Z Output waveform.
ave
orm
Vzb voltage *125V ± 1V (*See Your Label)
r
ve
Waveform
(Vzb) Z Bias VR1 manipulates the
offset of this waveform segment.
230V p/p
100V
er/div 100uSec
TIP: The Z-Bias (VZB) Adjustment is a DC level adjustment.
This is only to show the effects of Z-Bias on the waveform.
TIP: To help lock the scope when capturing the Z-SUS Waveform, us the
VS DA TP on the Control Board for an External Clock
June 2011 42PW350 Plasma
75
This Waveform is just for reference to observe the effects of Zbz adjustment
_
.