EasyManua.ls Logo

LG 42PW350 - Y-SUS 18 V Fuse Information

LG 42PW350
167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Y-SUS 18V Fuse Information
Location
Location
FS501
(
18V
)
()
2A/125V
FS501 Protects 18V line (created by D506 and T502). 18V is
used on the Y-SUS and leaves the Y-SUS on P101 pins 28~30 to
the Control Board. Then leaves the Control board on P2 pins
the
Control
Board.
Then
leaves
the
Control
board
on
P2
pins
13~15 and goes to the Z-SUS arriving on P201 pins 1~3.
Diode Check with Board Disconnected.
0.5V Red Lead on Chassis Gnd
1 13V Black Lead on Chassis Gnd
Diode Check with Board Connected.
0.85V Black lead on Chassis Ground.
June 2011 42PW350 Plasma