10
Standard Operation
Operating Information
ڸ
ڽ
ڹ
ۂ ہ
ں
ڻ
ڿ
ۀ
<Commercial (Standard) Setting>
①
Operation Mode
Select the operation mode to set the desired mode.
- Details of operation mode
Operation
Mode
Description
Cool
It cools down the room with pleasant and
fresh air.
Heat It provides a warm breeze to the room.
Auto
The product automatically switches
between cooling and heating to provide
desired temperature to the room.
Dry
It removes moisture while providing weak
cooling.
Fan
The IDU runs the fan only Thermal off
condition.
Emergency
Heater
You select set to use the emergency
heater, you can select the emergency
heater mode to use the heater.
Air Purify Operates air purier only.
Power Heat
Power heating rapidly increases the room
temperature.
Power Cool
Power Cool rapidly reduces the room
temperature.
Himalaya
Cool
The local special function applied to
models in the India region quickly reduces
room temperature.
M’Dry
A local special dehumidication function
applied to models in India.
Stop
The indoor unit stops working.
– Residential (US) only.
ھ
ڽ
ڹ
ۃ ڼ
ں
ڻ
ڸ
<Residential (US) Setting>
NOTE
• The reason why the cool air isn’t coming out immediately
after cooling is started is because of its function to
protect the compressor. After 3 minutes, the compressor
operates, and a cold air comes out.
• The emergency heater is activated under emergency
heating conditions after the installation and related
settings.
• Depending on the product, some functions cannot be set.
②
Room Temperature
Displays room temperature.
③
Set Temperature
The set temperature area for the current operation mode is
displayed.
Setpoint
Type
Operation Mode Setting Temperature
Single
Cool 16 ~ 30 °C (60 ~ 86 °F)
Heat 16 ~ 30 °C (60 ~ 86 °F)
Auto
Exclusive
model for
cooling
Cold, Little Cold, Fine,
Little Hot, Hot
Model for
both cooling
/ heating
18 ~ 30 °C (64 ~ 86 °F)
Dual Auto
Cool 10 ~ 37.5 °C (50~99 °F)
Heat 4 ~ 32 °C (40~90 °F)
NOTE
• When using the dehumidification / fan mode operation,
you cannot set the desired temperature.
• The setting temperature may vary depending on the type
of indoor unit.