Section 5. Connecting to Campbell Scientific dataloggers
Alias LI710A(4)=vpd_l
Units vpd_l=kPa
Alias LI710A(5)=pa_l
Units pa_l=kPa
Alias LI710A(6)=ta_l
Units ta_l=%
Alias LI710A(7)=rh_l
Units rh_l=C
Alias LI710A(8)=seq_l
Units seq_l=count
Alias LI710A(9)=diag_l
Units diag_l=Dimensionless
DataTable (LI710group0,True,-1) 'creates and names a data
table
DataInterval(0,30,Min,10) 'specifies the interval for
writing to the table
Sample(9,LI710A,IEEE4)
EndTable
BeginProg
Scan (30,Min,1,0) 'specifies the interval for scanning for
new data
SDI12Recorder(LI710A,C1,0,"XT!",1.0,0) 'instructs the SDI-
12 device on terminal C1 to start sampling
SDI12Recorder(LI710A,C1,0,"M0!",1.0,0) 'requests group 0
(M0) from the SDI-12 device on terminal C1
CallTable LI710group0
NextScan
5-8 LI-710 Evapotranspiration Sensor Instruction Manual