PD-XX (Expansion parameter)
PD-00
(Re-on)
ADR
The setting of the branch number
Communication
address:
0300H
0301H
Initial value
7F
Control mode
ALL
Unit
N/A
Configuration range
1 ~ 0x7F
Data size
16bit
Data format
Hex
When RS-232/RS-485 is used for communication, only one branch number may be set per servo drive.
If one branch number is set for multiple drives, the communication would not work properly. The station
number implies the absolute address communication network. It is also applicable to RS-232/485.
PD-01
BRT
The communication transmission rate
Communication
address:
0302H
0303H
Initial value
33
Control mode
ALL
Unit
Bps
Configuration range
0 ~ 0x55
Data size
16bit
Data format
Hex
□□□□■: RS232
□□□■□: RS485
The following shows the definition of the setting value:
04800
19600
219200
338400
457600
5115200