EasyManuals Logo

LiteOn ISA-7-040-S1 User Manual

LiteOn ISA-7-040-S1
237 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #93 background imageLoading...
Page #93 background image
Lite-On Technology Corp.
Industrial Automation
93
Parameters related to the position control
Abbr.
Function
Initial
value
Unit
Control mode
Remark
P
S
T
CTLM
Setting for the input source of the control
mode and command
0
pulse
r/min
N-M
O
O
O
(Re-on)
CMPT
The setting for the input format of the
external pulse
2
N/A
O
(S-off)
STL
The setting for the speed and torque limit
0
N/A
O
O
O
(S-off)
ITQ1
Internal Torque Limit 1
100
%
O
O
O
ITQ2
Internal Torque Limit 2
100
%
O
O
O
ITQ3
Internal Torque Limit 3
100
%
O
O
O
EOUT
The setting for the detector output of the
pulse value
2048
pulse
O
O
O
(S-off)
MSPL
Maximum speed limit
rated
r/min
O
O
O
GRM1
Numerator of the Electronic Gear Ratio
(N1)
1
pulse
O
(S-off)
GRD
Denominator of the Electronic Gear Ratio
(M)
1
pulse
O
(S-off)
GRM2
Numerator of the Electronic Gear Ratio
(N2)
1
pulse
O
(S-off)
GRM3
Numerator of the Electronic Gear Ratio
(N3)
1
pulse
O
(S-off)
GRM4
Numerator of the Electronic Gear Ratio
(N4)
1
pulse
O
(S-off)
ATL
Response level for automatic negotiation
20
O
O
(S-off)
(R-only)
This indicates the read-only register, which can only be used for reading status values.
(S-off)
This indicates Servo Off, which can be set only when the servo is off.
(Re-on)
This implies that the parameter is valid when the servo is booted again.
(N-keep)
The set content value won't be memorized by the parameter after power off.