The status and setting of the digital input
Communication
address:
0340H
0341H
For the setting not configured when the software specifies a DI status (PD-06 = 0), this parameter displays the DI
status (read-only).
For the setting configured when the software specifies a DI status (PD-06 = 1), this parameter may force to specify the
DI status. Bit0 ~Bit8 corresponds to DI1~DI9, respectively.
The record of the abnormal condition (N)
Communication
address:
0342H
0343H
Parameter function: The latest abnormal status record
LED displays ALXXX. XXX is an alarm code. Refer to the Drive Alarm List in 9.1.
The record of the abnormal condition (N-1)
Communication
address:
0344H
0345H
Parameter function: The second-last abnormal status record.