0. If these equal to 0, the resonance frequency point is not found. Do not increase the values of PB-11 and
PB-13 manually; otherwise the system deterioration might occur.
PB-15 Function Table
PB-15
Current value
PB-15
Value to be
modified
Function
0
1
Clear the values of PB-12~ PB-1x to activate the auto resonance
suppression.
0
2
Clear the values of PB-12~ PB-1x to activate the auto resonance
suppression.
1
0
Store the current values of PB-12~ PB-1x to deactivate the auto
resonance suppression.
1
1
Clear the values of PB-12~ PB-1x to activate the auto resonance
suppression.
1
2
Do not clear the values of PB-12~ PB-1x and keep the auto
resonance suppression active.
2
0
Store the current values of PB-12~ PB-1x to deactivate the auto
resonance suppression.
2
1
Clear the values of PB-12~ PB-1x to activate the auto resonance
suppression.
2
2
Do not clear the values of PB-12~ PB-1x and keep the auto
resonance suppression active.