77
Servo off, set PB-33 = 1
Operate with Jog or not
Set jog target speed in
PD-30
Operation speed up
or down
˙ Reduce PB-32 setting
˙
Or modify PB-10 to
reduce mechanical
resonance. Refer to
7.3.7.
Continuous vibration
or noise from the
mechanism
Panel displays stable
load inertia
Satisfactory
Done
Increase PB-32 setting
for higher response
and rigidity