EasyManua.ls Logo

LS Industrial Systems XBC-E Series - Chapter 6 Instruction and Flag List; 6.1 Classifications of Instructions

LS Industrial Systems XBC-E Series
542 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 Instruction and Flag List
XBC E-Type Main Unit 6-1 Ver. 1
Chapter 6 Instruction and Flag List
6.1 Classifications of Instructions
Classification Instructions Details Remarks
Basic
Instructions
Contact Point LOAD, AND, OR related Instructions
Unite AND LOAD, OR LOAD, MPUSH, MLOAD, MPOP
Reverse
NOT
Master Control MCS, MCSCLR
Output
OUT, SET, RST, 1 Scan Output Instruction, Output Reverse
Instruction (FF)
Sequence/Last-
input Preferred
Step Control Instruction ( SET Sxx.xx, OUT Sxx.xx )
End
END
Non-Process NOP
Timer
TON, TOFF, TMR, TMON, TRTG
Counter CTD, CTU, CTUD, CTR
Application
Instructions
Data Transfer Transfers specified Data, Group, String
4/8/64 Bits
available
Conversion
Converts BIN/BCD of specified Data & Group
4/8 Bits available
Data Type
Conversion
Converts Integer/Real Number
Output Terminal
Compare
Saves compared results in special relay
Compare to
Unsigned
Input Terminal
Compare
Saves compared results in BR. Compares Real Number, String &
Group. Compares 3 Operands
Compare to
Signed
Increase/Decrease Increases or decreases specified data 1 by 1 4/8 Bits available
Rotate
Rotates specified data to the left and right,
including Carry
4/8 Bits available
Move Moves specified data to the left and right, word by word, bit by bit 4/8 Bits available
Exchange Exchanges between devices, higher & lower byte, group data
BIN Operation
Addition, Subtraction, Multiplication & Division for Integer/
Real Number, Addition for String, Addition & Subtraction for Group
BCD Operation Addition, Subtraction, Multiplication, Division.
Logic Operation
Logic Multiplication, Logic Addition, Exclusive OR, Exclusive NOR,
Group Operation
System Error Display, WDT Initialize, Output Control, Operation Stop, etc.
Data Process
Encode, Decode, Data Disconnect/Connect, Search, Align, Max.,
Min., Total, Average, etc.
Data Table Process Data Input/Output of Data Table
String Process
String related Convert, Comment Read, String Extract, ASCII
Convert, HEX Convert, String Search, etc.
Special Function
Trigonometric Function, Exponential/Log Function, Angle/ Radian
Convert, etc.
Data Control Max/Min Limit Control, Dead-zone Control, Zone Control
Time related Date Time Data Read/Write, Time Data Adjust & Convert
Diverge
JMP, CALL
Loop FOR/NEXT/BREAK
Flag related
Carry Flag Set/Reset, Error Flag Clear
Special/Comm
related
Data Read/Write by BUSCON Direct Access
Interrupt related Interrupt Enable/Disable
Signal Reverse Reverse Integer/Real Signals, Absolute Value Operation
File related Block Read/Write/Compare/Convert, Flash data Transmission