EasyManua.ls Logo

LS Industrial Systems XBC-E Series - Special Functional Instruction

LS Industrial Systems XBC-E Series
542 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 Instruction Details
XBC E-Type Main Unit 6-258 Ve r. 1
6.35 Special Functional Instruction
6.35.1 SIN, SINP
Instruction
Area Available
Step
Flag
P M K F L T C S Z D.x
R.x
Con
st
U N D R
Error
(F110)
Zero
(F111)
Carry
(F112)
SIN(P)
S
O
O
O
-
O
O
O
-
-
-
-
O
O
O
O
O
2~4 - - -
D
O
O
O
-
O
-
-
-
-
-
-
-
O
O
O
O
Operand Description Data Size
S Input angle value (Radian) of Sine operation LREAL
D
Device number to save operation result in
LREAL
1) SIN (Sine)
(1) Performs SIN operation of data value in specified area S to save in D. Data type of S and D is Double real
and internal operation will be processed after conversion to Double real data.
(2) Input value is of radian. Refer to RAD for details on Conversion of angle to radian.
(3) If S’s value is 1.047…(π/3 rad = 600), operation result is 0.8660… (
23
).
2) Program Example
P00001
P00000
RAD M0008 M0000
SIN M0000 M0004
Converts the degree inputted at M0008, M0009 into radian value, and saves them at M0000, M0001. It
executes SIN operation and saves them at M0004, M0005 by conversion value.
SIN
SINP
S
D
SINP
SIN
S
D

Table of Contents