Chapter 6 Instruction Details
XBC E-Type Main Unit 6-315 Ve r. 1
2) Program Example
(1) Where the 40-word data of D1000 ~ D1039 is written in special module’s starting memory address 10 ~
50 installed on the slot number 7 of No.0 base when M00000 is On.
M00000
PUT h07 10 D1000 40
(2) Where the 3-word data of word M00010 ~ M00012 is written in A/D module’s internal memory address 5
~ 7 installed on the slot number 3 of No.0 base.
M00000
PUT h03 5 M00010 3
M00010
M
00011
10
20
M area of CPU
M00012 30
5
6
Address
10
20
A/
D module’s common
RAM
730