(b
) Operation command
Parameter
Device area per channel
Ch 0 Ch 1 Ch 2 Ch 3 Ch 4 Ch 5 Ch 6 Ch 7
Counter enabling K2600 K2700 K2800 K2900 K21800 K21900 K22000 K22100
Internal preset designation
of counter
K2601 K2701 K2801 K2901 K21801 K21901 K22001 K22101
External preset enabling of
counter
K2602 K2702 K2802 K2902 K21802 K21902 K22002 K22102
Designation of decremental
counter
K2603 K2703 K2803 K2903 K21803 K21903 K22003 K22103
Comp. output 0 enabling K2604 K2704 K2804 K2904 K21804 K21904 K22004 K22104
Comp. output 1 enabling K2607 K2707 K2807 K2907 K21807 K21907 K22007 K22107
Enabling of revolution time
per unit time
K2605 K2705 K2805 K2905 K21805 K21905 K22005 K22105
counter
K2606 K2706 K2806 K2906 K21806 K21906 K22006 K22100
Carry signal (Bit) K2610 K2710 K2810 K29100 K21810 K21910 K22010 K22110
Borrow signal K2611 K2711 K2811 K29101 K21811 K21911 K22011 K22111
Comp. output 0 signal K2612 K2712 K2812 K29102 K21812 K21912 K22012 K22112
Comp. output 1 signal K2613 K2713 K2813 K29103 K21813 K21913 K22013 K22113
(c) Area of monitoring
Parameter
Device area per channel
Ch 0
Ch 1 Ch 2 Ch 3
Ch 4
Ch 5 Ch 6 Ch 7
Current counter value K262 K272 K282 K292 K2182 K2192 K2202 K2212
Revolution per unit time K264 K274 K284 K294 K2184 K2194 K2204 K2214