Lightcommander Lightcommander
Lightcommander Lightcommander
Lightcommander
11
11
1
2/22/2
2/22/2
2/2
eMail: info@malighting.de
.
Tel.: +49 931 497940
.
User's Manual Lightcommander 12/2
2121
2121
21
THEATRE MODE
From version 1.26 there is one new mode in the Lightcommander 12/2 for programming a chaser.
It is now possible to assign a special fadetime to every single chaser step. This mode is called
THEATRE MODE.
Conditions for the THEATRE MODE
- The chaser may not run by sound or automatically
- Manual fading must be off
- The INSERT mode must be inactive
- The THEATRE mode must be activated (see below)
Programming the fadetimes
- After saving one step by ENTER (see user´s manual p. 12 and 14)
appears this menu
- While editing of programmed steps the corresponding time will be
shown instead of 0.00
- By turning the encoder the value can be changed between 0.00
and 10.0 seconds
- Storing the value by the CONT button
- Then the next step can be programmed or edited
- The fadetimes are part of the chaser and will be saved also to the
memory card.
Activating the THEATRE MODE
- SHIFT +UTILITY" and within the next menu MORE leds you to the
THEATRE MODE
- By pressing the button THEATRE MODE this mode will be activated
(stripebefore the word "MODE" indicates mode ON)
- While the THEATRE mode is active, there is a vertical line within the
squares of the lower row in the main menu
Even if the THEATRE MODE is activated as described above, any changes made
will not take effect until all conditions described in section 1 are met!
Working in the THEATRE MODE
- As soon as all mentioned conditions are fulfilled, for the NEXT step the times
saved according to 2. are relevant; the times adjusted by the XFADE fader
are invalid.
- By moving the XFADE fader changing of the actual fade time is possible.
The fader will be fixed at the given value (grab, analogue to editing of
memories).
- After inactivating the THEATRE mode by the criterion mentioned above the
actual fade will be finished using the value set by the XFADE fader.
+
SHIFT UTILITY 2
FADETIME: 0.00S
CONT