Flex 8EX / 12EX EU System Instruction Manual
March 2018
Page 42 of 66
2. 4 output relay configuration with Opened/Closed contact at 2nd speed*
At 2nd speed, only the 2nd speed (F2 or R2) output relay is closed.
3. 4 output relay configuration with Closed/Closed contact at 2nd speed*
At 2nd speed, both 1st speed (F1 or R1) and 2nd speed (F2 or R2) output relays are
closed.
4. 4 output relay configuration with Forward and Fast output relays engaged at
2nd speed*
5. 4 output relay configuration with Forward, Slow, and Fast output relays
engaged at 2nd speed*
NOTE: See Section 4.2.4 on page 45 on how to set this function.
R2F2R1F1 R2F2R1F1
Forward 1
st
speed pushbutton pressed Forward 2
nd
speed pushbutton pressed
↓↓
F1 R1 F2 R2R2F2R1F1
Forward 1
st
speed pushbutton pressed Forward 2
nd
speed pushbutton pressed
↓↓
Fwd Rev
Slow
FastFwd Rev
Slow
Fast
Forward 1
st
speed pushbutton pressed Forward 2
nd
speed pushbutton pressed
↓↓
Fwd Rev
Slow
Fast Fwd Rev
Slow
Fast
Forward 1
st
speed pushbutton pressed Forward 2
nd
speed pushbutton pressed
↓↓