Flex 8EX / 12EX EU System Instruction Manual
March 2018
Page 49 of 66
Manufacture preset
Jumper Settings Function
JP3
(Blank)
After 1 minute (depending on the Continuous Transmitting
Time Adjustment setting in Section 4.1.2 on page 25) of
transmitter inactivity (MAIN deactivated), press any push-
button on the transmitter to reactivate the receiver MAIN.
JP3
(Inserted)
After 1 minute (depending on the Continuous Transmitting
Time Adjustment setting in Section 4.1.2 on page 25) of
transmitter inactivity (MAIN deactivated), rotate the trans-
mitter power key switch to the START position to reactivate
the receiver MAIN.
JP4
(Blank)
JP5
(Blank)
Standard right-to-left pushbutton configuration for all
models
JP4
(Inserted)
JP5
(Blank)
In-line pushbutton configuration (top to bottom) for Flex
8ES/EX
JP4
(Blank)
JP5
(Inserted)
In-line pushbutton configuration (top to bottom) for Flex
12ES/EX
JP4
(Inserted)
JP5
(Inserted)
In-line pushbutton configuration (top to bottom) for Flex
4ES/EX
JP6
(Blank)
Program system serial number/ID code and channel from
decoder module to I-CHIP
JP6
(Inserted)
Program system serial number/ID code and channel from
I-CHIP to decoder module
JP7
(Inserted)
For system test only, receiver MAIN is disabled