Guided Wave Radar
Level Transmitter
Enhanced Model 705
Software v3.x
Installation and Operating Manual
2014/68/EU

Table of Contents

Other manuals for Magnetrol eclipse 705

Questions and Answers

  • B
    Benjamin SimmonsAug 31, 2025
    What does 'EOP
    • A
      Alan NashAug 31, 2025
      If the End of Probe signal from a dry probe is out of range, ensure the Probe Length is entered correctly and set the Dielectric to a lower dielectric range. Also, ensure proper Blocking Distance.
  • A
    Anthony KeithAug 25, 2025
    Why are LEVEL readings on Magnetrol Measuring Instruments consistently inaccurate?
    • D
      Daniel VillanuevaAug 25, 2025
      If LEVEL readings are consistently high or low by a fixed amount, the configuration data might not accurately match the probe length or tank height. Ensure the proper Probe Model, Level Offset, or probe length is configured. You can also adjust the trim level value by the amount of noted inaccuracy.
  • J
    Jill BakerAug 25, 2025
    What to do if the LEVEL reading is stuck at full scale on Magnetrol eclipse 705?
    • L
      leslie71Aug 26, 2025
      If the LEVEL reading on the display is stuck at full scale, the software might believe the probe is flooded. Check the actual level. If the probe isn't flooded, inspect for buildup or obstructions near the top of the probe. You may also select a higher dielectric range, check for condensation in the probe connection, or add Blocking Distance.
  • S
    Samuel WarrenAug 26, 2025
    How to troubleshoot inaccurate LEVEL and % OUTPUT values on Magnetrol Measuring Instruments?
    • L
      Linda ThomasAug 26, 2025
      If the LEVEL and % OUTPUT values are inaccurate, the basic configuration data might be questionable, or the interface level may have significant emulsion. You can reconfigure the Probe Model, Probe Mount, Probe Length, or Level Offset. Also, examine the process to reduce or eliminate the emulsion layer.
  • C
    coxdanielleAug 27, 2025
    What causes high LEVEL and % OUTPUT readings on Magnetrol eclipse 705?
    • D
      Daniel MosesAug 27, 2025
      If the LEVEL and % OUTPUT values are reading high compared to the actual level, there might be an obstruction in the tank affecting the single rod probe. Increase the Dielectric Range until the obstruction is ignored or relocate the probe away from the obstruction.
  • J
    Jessica HamiltonAug 27, 2025
    Why are LEVEL and % OUTPUT values at maximum on Magnetrol Measuring Instruments?
    • C
      Cynthia AlexanderAug 27, 2025
      If the LEVEL and % OUTPUT values are all at the maximum level, there might be a configuration issue with the single rod probe. Increase the Blocking Distance or increase the Dielectric Range.
  • C
    Charles VillaAug 28, 2025
    What to do if LEVEL and % OUTPUT values are reading low on Magnetrol eclipse 705?
    • M
      mwallAug 28, 2025
      If the LEVEL and % OUTPUT values are all reading low compared to the actual level, it could be due to a lower dielectric material over a higher dielectric material, such as oil over water. In this case, select the Fixed Threshold option.
  • L
    Lucas JamesAug 29, 2025
    How to fix 'No Signal' error on Magnetrol Measuring Instruments?
    • B
      Belinda BrownAug 29, 2025
      If there is no signal being detected, ensure the Dielectric setting is correct for the measured medium. Also, increase the Sensitivity and confirm the Probe Model is proper for the dielectric of the medium.
  • J
    John HayesAug 29, 2025
    How to resolve a weak signal on Magnetrol eclipse 705 Measuring Instruments?
    • M
      Michael DavisAug 30, 2025
      If the signal amplitude is lower than desired, set the Dielectric to a lower range value and increase the Sensitivity.
  • E
    Emily McguireAug 30, 2025
    Why is the LEVEL value reading high when it should be zero on Magnetrol eclipse 705 Measuring Instruments?
    • L
      Lisa HarrisAug 30, 2025
      If the LEVEL value is reading high when it should be zero, the transmitter might be loose or disconnected from the probe. Ensure the transmitter is securely connected to the probe.

Summary

QuickStart Installation

Getting Started

Prerequisites and initial steps for installation.

QuickStart Mounting

Procedures for mounting the transmitter and probe.

QuickStart Wiring

Steps for making electrical connections.

QuickStart Configuration

Basic setup and configuration of the transmitter.

Complete Installation

Unpacking

Procedures for safely unpacking the instrument.

Electrostatic Discharge (ESD) Handling Procedure

Safety guidelines for handling sensitive electronic components.

Before You Begin

Preparatory checks and considerations before installation.

Mounting

Details on probe and transmitter mounting procedures.

Installing a Coaxial Probe

Specific steps for installing coaxial probes.

Installing a Twin Rod Probe

Specific steps for installing twin rod probes.

Installing a Single Rod Probe

Specific steps for installing single rod probes.

Installing the Transmitter

Procedures for attaching the transmitter unit.

Wiring

Electrical connection procedures.

General Purpose or Non-Incendive (CI I, Div. 2)

Wiring instructions for general purpose installations.

Intrinsically Safe

Wiring requirements for intrinsically safe installations.

Explosion Proof

Wiring procedures for explosion-proof environments.

Configuring the Transmitter

Setup and calibration procedures.

Transmitter Display and Keypad

Details on using the transmitter's interface and controls.

Model 705 Menu: Step-By-Step Procedure

Detailed configuration steps for the Model 705 menu.

Measurement Type: Level Only (Loop Control = Level)

Configuration steps for level-only measurement.

Measurement Type: Level and Volume (Loop Control = Volume)

Configuration for level and volume measurement.

Measurement Type: Interface Level (Loop Control = Interface Level)

Configuration for interface level measurement.

Offset Description

Explanation of the Level Offset parameter.

Strapping Table Description

Procedure for linearizing output for odd-shaped vessels.

Configuration Using HART

Setup and communication via HART.

Connections

How to connect a HART communicator.

Display Menu

Overview of the HART communicator's display menu.

FOUNDATION fieldbus Digital Communications

Details on integrating with Fieldbus systems.

Description

Overview of FOUNDATION fieldbus system.

Device Configuration

Configuration steps for Fieldbus devices.

Reference Information

Description

General overview of the ECLIPSE Level Transmitter.

Theory of Operation

Explanation of the technology and principles.

Micropower Impulse Radar

Explanation of the MIR technology.

Interface Detection

How the device detects interface levels.

Troubleshooting

Diagnosing and resolving common problems.

Troubleshooting System Problems

Common system issues and their solutions.

Status Messages

Interpreting diagnostic messages and status indicators.

Agency Approvals

Certifications and compliance standards.

Parts

Information on replacement and spare parts.

Replacement Parts

List of components available for replacement.

Specifications

Technical details and performance data.

Functional

Functional characteristics and parameters.

Performance - Model 705

Performance metrics and accuracy details.

Physical

Physical dimensions and mounting information.

Model Numbers

Product identification codes.

Transmitter

Breakdown of transmitter model number codes.

Probe

Breakdown of probe model number codes.

Glossary

Assured Quality & Service

Service Policy

Details on warranty, repairs, and service.

Return Material Procedure

Steps for returning materials for service or repair.

Magnetrol eclipse 705 Specifications

General IconGeneral
BrandMagnetrol
Modeleclipse 705
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals