MP2600D, MP2600C & MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 46 of 52
V.24 cable rate and transmission distance:
Baud rate (bps) Maximum transmission distance (m)
2400 60
4800 60
9600 30
19200 30
38400 20
64000 20
115200 10
V.35 cable rate and transmission distance:
Baud rate (bps) Maximum transmission distance (m)
2400 1250
4800 625
9600 312
19200 156
38400 78
56000 60
64000 50
2048000 30