COMMONRAILSYSTEM
Removingthemasterhigh-pressurepump
•Disconnectthemeteringunitelectricalconnection
•Removethehigh-pressurepump(1)withdrive
housing(2)
•RemovetheO-rings(3)and(4)
•Cleanthesealingsurfaces
Installingthehigh-pressurepump
Installingthemasterhigh-pressurepump
•Cleanthesealingsurfaces
•Insertthehigh-pressurepump(1)anddrive
housing(2)withnewO-rings(3)and(4)
•Connectthemeteringunitelectricalconnection
Screwinginthehigh-pressurepumpmounting
bolts
•Screwinandtightenthemountingbolts(1)
Attachingthecover
•Cleanthesealingsurfaces
•Positionthecover(2)withanewseal(3)
•Screwinandtightenthemountingbolts(1)
AE63stedition133