ENGINEELECTRICS
WARNING
Electricalcabledamageduetoovertightening
•FollowtheoperatinginstructionsfortheCabletiepliers[2]
WARNING
Restrictedoperationduetoincorrectentriesinthefaultmemory
•Beforeremovingtheenginecontrolunit,readoutanddocumentthefaultmemory
WARNING
Dangerofirreparableenginecontrolunitdamage
•Wheninstallingtheconnectors,rstfullyopenthelockandtheninsertandlocktheconnectors
WARNING
Dangerofirreparableplugconnectiondamage
•Protectloosenedplugconnectionsandcontactsagainstdirtingress
WARNING
Dangerofcablebreakage
•Onlysecurethewiringharnessatthepreviouslymarkedattachmentpoints
Note
Marktheattachmentpointsbeforeremovingtheenginewiringharness
Note
Afteranewenginecontrolunitistted,itsparametershavetobereset.
Afterresettingtheenginecontrolunitparameters,readoutthefaultmemoryanddeleteas
necessary.
Specialtools
[2]
Cabletiepliers
•Tighteningandcuttingoffthecableties
08.02960-0100
28AE63stedition