–99–
EC20 (WITHOUT TIMER) SELF-CONTAINED AIR-COOLED — STANDARD CUBE
NOTE: These characteristics may vary depending on operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Continued on next page …
Air Temp.
Entering
Condenser
°C
Freeze Time
Harvest
Time
Times in minutes.
Water Temperature °C
10 15 20 25 30 35 40
10 19.1-21.4
3.5 min.
15 19.7-22.1 19.8-22.2
20 21.2-23.8 21.4-23.9 21.5-24.1 21.7-24.3 21.4-23.9
25 22.8-25.5 24.0-26.8 23.3-26.0 23.4-26.2 23.6-26.4
30 24.7-27.6 24.9-27.8 25.1-28.1 25.3-28.3 25.7-28.7 25.9-29.0 26.1-29.2
35 27.7-30.9 27.7-30.9 27.9-31.1 28.1-31.4 28.6-31.9
40 30.7-34.3 31.0-34.6 31.3-34.9
45 34.1-38.0 34.6-38.4 34.8-38.8

Table of Contents