–129–
EC50 SELF-CONTAINED AIR-COOLED — LARGE CUBE
NOTE: These characteristics may vary depending on operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Continued on next page …
Air Temp.
Entering
Condenser
°C
Freeze Time
Harvest
Time
Times in minutes.
Water Temperature °C
10 15 20 25 30 35 40
10 24.8-26.7
3.5 min.
15 26.8-28.7 27.8-29.8
20 29.0-31.1 30.2-32.4 31.5-33.8 32.2-34.5 33.7-36.1
25 31.5-33.8 32.9-35.3 33.7-36.1 35.3-37.8 37.1-39.7
30 34.5-36.9 36.2-38.7 37.1-39.7 39.0-41.8 41.1-44.0 43.5-46.5 46.1-49.3
35 41.1-44.0 43.5-46.5 46.1-49.3 49.0-52.4 52.3-55.9
40 52.3-55.9 56.0-59.9 60.3-64.4
45 60.3-64.4 65.2-69.6 70.9-75.7