–156–
EC80 SELF-CONTAINED WATER-COOLED — STANDARD CUBE
NOTE: These characteristics may vary depending on operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp. Around
Ice Machine
°C
Freeze Time
Harvest Time
Times in minutes.
Water Temperature °C
10 15 20 25 30 35 40
10 16.2-18.3
3.0 min.
15 16.4-18.6 18.2-20.6
20 16.7-18.9 18.2-20.6 20.0-22.5 22.0-24.8 25.0-28.1
25 17.0-19.2 18.9-21.3 20.3-22.9 22.5-25.3 25.0-28.1
30 17.0-19.2 18.5-20.9 20.3-22.9 22.5-25.3 25.0-28.1 28.1-31.6 32.0-35.8
35 20.7-23.4 22.9-25.8 25.6-28.8 28.8-32.3 32.9-36.8
40 25.6-28.8 29.6-33.2 33.8-37.9
45 26.2-29.4 29.6-33.2 33.8-37.9