–102–
EC30 SELF-CONTAINED AIR-COOLED — STANDARD CUBE
NOTE: These characteristics may vary depending on operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°C
Freeze Time
Harvest
Time
Times in minutes.
Water Temperature °C
10 15 20 25 30 35 40
10 16.5-18.8
3.5 min.
15 18.6-21.2 19.4-22.1
20 20.3-23.1 21.3-24.1 23.4-26.6 24.6-27.9 26.0-29.4
25 23.4-26.6 24.6-27.9 26.0-26.9 27.5-31.1 30.9-34.9
30 26.0-29.4 27.5-31.1 30.9-34.9 32.9-37.2 35.2-39.7 37.8-42.6 44.1-49.7
35 35.2-39.7 37.8-42.6 44.1-49.7 48.1-54.1 52.8-59.3
40 52.8-59.3 58.4-65.6 65.3-73.3
45 65.3-73.3 85.0-95.2 99.7-111.7