–141–
EC65 SELF-CONTAINED AIR-COOLED — LARGE CUBE
NOTE: These characteristics may vary depending on operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Continued on next page …
Air Temp.
Entering
Condenser
°C
Freeze Time
Harvest
Time
Times in minutes.
Water Temperature °C
10 15 20 25 30 35 40
10 28.1-30.0
3.0 min.
15 32.3-34.4 34.1-36.4
20 35.5-37.9 37.0-39.4 39.4-42.0 41.2-43.9 45.3-48.2
25 39.4-42.0 46.4-49.4 43.1-46.0 46.4-49.4 48.8-52.0
30 43.1-46.0 46.4-49.4 48.8-52.0 51.5-54.8 54.5-58.0 59.6-63.4 63.6-67.6
35 54.5-58.0 59.6-63.4 63.6-67.6 68.0-72.3 76.0-80.8
40 76.0-80.8 82.3-87.5 89.8-95.4
45 89.8-95.4 103.8-110.3 115.7-122.9